Schau mal rein im Ordner Sale% finden sich interessante Produkte mit besonders attraktiven Rabatten.
How many Lux are appropriate?
For the lighting of indoor and outdoor workplaces there are guideline values derived from European standards.
"Illumination of indoor workplaces", EN 12464-1 (June 2011)
"Illumination of outdoor worklplaces", EN 12464-2 (October 2007)
Examples of indoor guidelines:
- Break rooms: 100 Lux
- Bakeries: 300-500 Lux
- Study (office): 500 Lux, at least at the desk
- Sales areas: 300 Lux
- Classrooms, seminar rooms: 300 Lux
- Lecture halls: 500 Lux
- Corridors: 100 Lux
- Examination rooms (general lighting): 500 Lux
Examples for outdoor guidelines:
- Walkways, exclusively for pedestrians: 5 Lux
- Parking spaces (low, medium, high traffic): 5, 20, 20 Lux
- Covered platforms, long-distance traffic: 100 Lux
- Construction sites (construction areas): 50 Lux
Luxmeter - more than just an illuminance meter
There are lux meters that are designed solely for measuring luminous intensity. However, there are also devices that are true all-round talents and equipped with extensive measurement parameters.
These include temperature, air pressure, sound, and humidity.
To make your decision a little easier, there is an overview of the respective functions of the all-round lux meter or the pure lux meter.
Overview Luxmeter Allrounder:
| PCE-EM 882 | |||
Temperature | yes | yes | yes | yes |
Temperature with K-Type |
|
| yes | yes |
Air pressure | yes |
|
| yes |
Lux measurements | yes | yes | yes | yes |
Wind speed |
|
|
| yes |
Volume flow |
|
|
| yes |
Humidity | yes | yes | yes | yes |
Sound level |
| yes | yes |
|
Data logger | yes |
|
|
|
3-axis accelerator | yes |
|
|
|
Accessories |
| Puncture sensor | Infrared temperature adapter |
|
Multimeter |
|
| yes |
|
Measuring range |
|
| DC voltage AC voltage DC current AC current Resistor Capacity Frequency |
Overvie of pure lux meters:
| ||||
Calibration certificate | ICA |
| ICA | ICA |
Measuring ranges | 0,00-40.000 lux | 40 / 400 / 4000 / 40.000 / 400.000 lux | 40 / 400 / 4000 / 40.000 / 400.000 lux | 400 / 4000 / 40.000 / 400.000 lux |
Resolution | 0,01 lux |
| 0,01 / 0,1 / 1 / 10 / 100 lux | 0,1 / 1 / 10 / 100 lux |
Display | 5-digit LCD-Display | max. display 3999 Display of 40,000 / 400,000 lux | 3 3/4-digit LCD-Display | 3 3/4-digit LCD-Display |
Accuracy | ±10 % vom Messwert +5 Digits (Entspricht Klasse B / DIN 5032 Teil 7) | ± 3% (with a standard incandescent bulb | ± 5% of reading ± 10 digits (<10,000 lux) ± 10% of reading ± 10 digits (> 10,000 lux) | ±5 % of reading ±10 digits (<10.000 Lux) ±10 % of reading ±10 digits (>10.000 Lux) |
Measuring rate | 2 per second | 2,5 per second | 1,5 per second | 1,5 per second |
Operating condidtions | 0...40 °C | +5 ... +40 °C/ 0...70 % rF | 0...40 °C / 80 % r.F. | 0...40 °C / 80 % r.F. |
Memory |
| 99 readings |
| 16.000 readings |
Overload display | OL= Overload | OL= Overload | OL= Overload | OL= Overload |
Reproducibility |
| ± 3 % | ± 3 % | ± 3 % |