How many Lux are appropriate?
For the lighting of indoor and outdoor workplaces there are guideline values derived from European standards.
"Illumination of indoor workplaces", EN 12464-1 (June 2011)
"Illumination of outdoor worklplaces", EN 12464-2 (October 2007)
Examples of indoor guidelines:
- Break rooms: 100 Lux
- Bakeries: 300-500 Lux
- Study (office): 500 Lux, at least at the desk
- Sales areas: 300 Lux
- Classrooms, seminar rooms: 300 Lux
- Lecture halls: 500 Lux
- Corridors: 100 Lux
- Examination rooms (general lighting): 500 Lux
Examples for outdoor guidelines:
- Walkways, exclusively for pedestrians: 5 Lux
- Parking spaces (low, medium, high traffic): 5, 20, 20 Lux
- Covered platforms, long-distance traffic: 100 Lux
- Construction sites (construction areas): 50 Lux
Luxmeter - more than just an illuminance meter
There are lux meters that are designed solely for measuring luminous intensity. However, there are also devices that are true all-round talents and equipped with extensive measurement parameters.
These include temperature, air pressure, sound, and humidity.
To make your decision a little easier, there is an overview of the respective functions of the all-round lux meter or the pure lux meter.
Overview Luxmeter Allrounder:
| PCE-EM 882 | |||
Temperature | yes | yes | yes | yes |
Temperature with K-Type |
|
| yes | yes |
Air pressure | yes |
|
| yes |
Lux measurements | yes | yes | yes | yes |
Wind speed |
|
|
| yes |
Volume flow |
|
|
| yes |
Humidity | yes | yes | yes | yes |
Sound level |
| yes | yes |
|
Data logger | yes |
|
|
|
3-axis accelerator | yes |
|
|
|
Accessories |
| Puncture sensor | Infrared temperature adapter |
|
Multimeter |
|
| yes |
|
Measuring range |
|
| DC voltage AC voltage DC current AC current Resistor Capacity Frequency |
Overvie of pure lux meters:
| ||||
Calibration certificate | ICA |
| ICA | ICA |
Measuring ranges | 0,00-40.000 lux | 40 / 400 / 4000 / 40.000 / 400.000 lux | 40 / 400 / 4000 / 40.000 / 400.000 lux | 400 / 4000 / 40.000 / 400.000 lux |
Resolution | 0,01 lux |
| 0,01 / 0,1 / 1 / 10 / 100 lux | 0,1 / 1 / 10 / 100 lux |
Display | 5-digit LCD-Display | max. display 3999 Display of 40,000 / 400,000 lux | 3 3/4-digit LCD-Display | 3 3/4-digit LCD-Display |
Accuracy | ±10 % vom Messwert +5 Digits (Entspricht Klasse B / DIN 5032 Teil 7) | ± 3% (with a standard incandescent bulb | ± 5% of reading ± 10 digits (<10,000 lux) ± 10% of reading ± 10 digits (> 10,000 lux) | ±5 % of reading ±10 digits (<10.000 Lux) ±10 % of reading ±10 digits (>10.000 Lux) |
Measuring rate | 2 per second | 2,5 per second | 1,5 per second | 1,5 per second |
Operating condidtions | 0...40 °C | +5 ... +40 °C/ 0...70 % rF | 0...40 °C / 80 % r.F. | 0...40 °C / 80 % r.F. |
Memory |
| 99 readings |
| 16.000 readings |
Overload display | OL= Overload | OL= Overload | OL= Overload | OL= Overload |
Reproducibility |
| ± 3 % | ± 3 % | ± 3 % |